ZB4-30 Self-Priming Pump
You are here: Home » Products » Permanent Magnet Variable Frequency Pump » ZB4-30 Self-Priming Pump

loading

ZB4-30 Self-Priming Pump

Usage Scenarios
It is most widely used in places with clean water as the main medium, such as household water, small office buildings, and rural buildings.

Product Attributes
The temperature of the conveying medium shall not exceed 60 ℃;
The pH value of the medium is between 6.5 and 8.5.
The volume ratio of solid impurities in water shall not exceed 0.1%, and the particle size shall not exceed 0.2mm.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Product Name Series Model Power
(w)
Rated Flow
(m³/h)
Rated Head
(m)
Max Flow
(m³/h)
Max Head
(m)
Rated Voltage
(V)
Rated Current
(A)
Impeller
(Stages)
Speed Range
(r/min)
Inlet/Outlet Size Insulation Class
Frequency
Protection Level Self-priming Height Water Temp. Range
PM VFD Self-Priming Constant Pressure Pump ZB ZB4-30 400 W 2 m³/h 18 m 4 m³/h 30 m 220 V 2.9 A 2 2500~5600r/min DN25 F 50Hz/60Hz IPX4 5 m ≤60 ℃


Product Overview


The ZB4-30 is a reliable foundational PM VFD Self-Priming Constant Pressure Pump for clean water applications. As a core model in the ZB series, it features a 400W rated power, 2 m³/h rated flow, and 18 m rated head, with a maximum flow of 4 m³/h and maximum head of 30 m. Its 5 m self-priming height simplifies water extraction, and it operates with water temperatures up to 60℃. With an IPX4 protection level, DN25 ports, and 2-stage impeller, it prioritizes ease of use and durability—ideal for users with basic, consistent water supply needs (e.g., urban flats, small offices).


Core Product Features


Stable Daily Performance

Consistent flow & head: 2 m³/h rated flow meets the needs of a 4–5 person family, while 18 m head ensures steady pressure for daily use.

2-stage impeller: Reduces pressure fluctuations when using multiple water outlets (e.g., washing machine + tap).


Cost-Effective Reliability

No complex controls: Easy to operate for users without technical expertise, reducing setup time.

Long service life: Insulation Class F and robust motor design extend durability, lowering replacement costs.


Easy Installation

DN25 standard ports: Fits most residential plumbing, no need for custom adapters.

Compact size: Installs in utility closets or small equipment rooms, saving space.


Scenario-Specific Solutions


Urban Flat Water Pressurization

Solves municipal water pressure issues: Boosts tap water pressure for showers, dishwashing, and toilet use in urban apartments.

Non-intrusive: Works with existing pipelines without modifying the main water supply.


Small Office Building Supply

Supports 10–20 employee offices: Provides water for handwashing, cleaning, and pantry needs.

Quiet operation: Low noise levels avoid disrupting office work during operation.


Rural Domestic Use

Well water extraction: Draws water from 5 m depths for drinking, cooking, and gardening.

Dust-resistant: IPX4 protection handles rural outdoor conditions, suitable for installation near wells.


Under Floor Heating Circulation

Under Floor Heating Circulation

Cooling Of Industrial Equipment

Cooling Of Industrial Equipment

Hot Water Facilities For Bath Places/Clubs

Hot Water Facilities For Bath Places/Clubs

Solar Energy Circulation

Solar Energy Circulation

Air Energy Circulation

Air Energy Circulation

Water Supply From The Water Tower

Water Supply From The Water Tower


Our Certificate

certificates


Packing & Shipping

Packing & shipping

Packing & shipping

PAYMENT   T/T,Westem Union,MoneyGram,Paypal

DELIVERY Safe,Fast,and Effective

Packing & shipping



FAQ


Q: What maintenance does the ZB4-30 require?

A: 1) Clean the inlet filter monthly to prevent impurity blockages; 2) Avoid dry operation (stops motor damage); 3) Check wiring annually for wear. With proper care, it lasts 5–8 years.


Q: Can it circulate solar-heated water?

A: Yes—its 60℃ temp limit works with solar water systems. Ensure the water’s pH and impurity levels meet the pump’s requirements.


Q: Why won’t the pump self-prime?

A: Check three things: 1) Inlet pipes for leaks (air leaks break self-priming); 2) Inlet filter for clogs (clean if needed); 3) First-use water fill (subsequent uses don’t need pre-filling if pipes are sealed).


Previous: 
Next: 
Since its founding in 2017, Zhejiang Eiiman Zhihui has rapidly risen to become an innovation leader in the industry, a modern technology enterprise that integrates research and development, production and sales.
 +86-15305860633
 BLDG-13-B Maozhuxia Industrial Zone Daxi Town Wenling Zhejiang China

Contact Us

If you have any questions or requirements, please feel free to contact our customer service team.
Follow Us
Our Products
Copyright © 2025 Zhejiang Eiiman Zhihui Technology Co., Ltd. All Rights Reserved. | Sitemap | Privacy Policy